Table 4-5. Bucket-ProTM System Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
FAULT 4-6. ELEVATION VALUE DOES NOT MATCH DESIRED VALUE.
Step 1.
Ensure correct bucket is selected in Setup menu.
Select correct bucket.
Step 2.
Check Laser setup.
Perform LASER REFERENCING setup (Chapter 5).
Step 3.
Check Mast mm/count setup in Edit Machine Dimensions setup menu.
If incorrect, reset measurements.
Step 4.
Sensor(s) (1) damaged.
Inspect Sensor(s) (1). If damaged, replace Sensor(s) (1).
Step 5.
Check Sensor(s) (1) calibration.
If calibration is incorrect, recalibrate (Para 4-32).
Step 6.
Check averaging or NORMAL/REVERSED setup in View Sensor menu.
Perform System Calibration (Para 4-32).