SECTION IV. BUCKET-PROTM SYSTEM TROUBLESHOOTING
Table 4-5. Bucket-ProTM System Troubleshooting (Cont)

Laser Leveling Equipment (Lle) For Graders, Dozers, & Scrapers Page Navigation
  185    186    187    188    189  190  191    192    193    194    195  
img
. . .
TM 5-6675-348-13&P
Table 4-5. Bucket-ProTM System Troubleshooting
Malfunction
Test or Inspection
Corrective Action
FAULT 4-1. BUCKET-PROTM SYSTEM/GRAPHIC DISPLAY DOES NOT TURN ON.
Step 1.
Ensure Power Cable (1) is connected.
Connect Power Cable (1).
Step 2.
Inspect Power Cable (1) for damage.
If Power Cable (1) is damaged, replace Power Cable (1).
Step 3.
Ensure Graphic Display Cable (2) is connected.
Connect Graphic Display Cable (2).
Step 4.
Check Fuse (3) at Remote Interface Box (4).
If Remote Interface Box (4) Fuse (3) is faulty, replace Fuse (3).
Step 5.
Check for 22 to 28 Vdc at Battery Connection (5).
If 22 to 28 Vdc is not found, service Battery.