TM 5-6675-348-13&P
Table 4-5. Bucket-ProTM System Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
FAULT 4-4. GRAPHIC DISPLAY NOT RESPONDING PROPERLY (DIRECTION, SPEED, LOCATION
WITH RESPECT TO GRADE).
Step 1.
Ensure Sensor(s) (1) are attached to correct Connector (2) on Remote Interface Box (3).
If incorrect, connect Sensor(s) (1) to proper location.
Step 2.
Sensor(s) (1) damaged.
Inspect Sensor(s) (1). If damaged, replace Sensor(s) (1).
Step 3.
If calibration is incorrect, perform System Calibration (Para 4-32).
Step 4.
Check Bucket-ProTM System benchmark reference.
Step 5.
Check Averaging or Normal/Reversed Setup in View Sensor menu.