Table 4-5. Bucket-ProTM System Troubleshooting (Cont)
Table 4-5. Bucket-ProTM System Troubleshooting (Cont)

Laser Leveling Equipment (Lle) For Graders, Dozers, & Scrapers Page Navigation
  188    189    190    191    192  193  194    195    196    197    198  
img
. . . . .
TM 5-6675-348-13&P
Table 4-5. Bucket-ProTM System Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
FAULT 4-4. GRAPHIC DISPLAY NOT RESPONDING PROPERLY (DIRECTION, SPEED, LOCATION
WITH RESPECT TO GRADE).
Step 1.
Ensure Sensor(s) (1) are attached to correct Connector (2) on Remote Interface Box (3).
If incorrect, connect Sensor(s) (1) to proper location.
Step 2.
Sensor(s) (1) damaged.
Inspect Sensor(s) (1). If damaged, replace Sensor(s) (1).
Step 3.
Check Sensor(s) (1) calibration.
If calibration is incorrect, perform System Calibration (Para 4-32).
Step 4.
Check Bucket-ProTM System benchmark reference.
Set Benchmark Elevation (Para 4-15).
Step 5.
Check Averaging or Normal/Reversed Setup in View Sensor menu.
Perform System Calibration (Para 4-32).
4-34