Table 4-5. Bucket-ProTM System Troubleshooting
Table 4-5. Bucket-ProTM System Troubleshooting (Cont)

Laser Leveling Equipment (Lle) For Graders, Dozers, & Scrapers Page Navigation
  186    187    188    189    190  191  192    193    194    195    196  
img
. . . .
TM 5-6675-348-13&P
Table 4-5. Bucket-ProTM System Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
FAULT 4-2. SENSORS DO NOT WORK.
Step 1.
Ensure Sensor Cables (1) are connected to proper Connector on Remote Interface Box (2).
Install Sensor Cables (1) on proper Remote Interface Box (2) Connector.
Step 2.
Ensure all Sensor Cables (1) are connected to Sensors (3).
Inspect Sensor Cable (1). Reconnect if disconnected, or replace if damaged.
Step 3.
Sensor(s) (3) are damaged.
Inspect Sensor(s) (3). If damaged, replace Sensor(s) (3).
Step 4.
Ensure Voltage Protection Cable is functioning.
Replace Voltage Protection Cable.
Step 5.
Check Averaging or Normal/Reversed Setup in View Sensor Menu.
Perform Setup Averaging again (Para 4-32).
Step 6.
Dual-Axis Tilt Sensor is not enabled in Setup Parameters in Setup menu (Dual-Axis Tilt
Sensor failure only).
Enable-Dual Axis Tilt Sensor (Para 4-32).