TM 5-6675-348-13&P
Table 4-5. Bucket-ProTM System Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
Step 1.
Ensure correct model Electric Mast (EM2E-24) is installed.
If wrong Electric Mast is installed, replace with EM2E-24 Electric Mast.
Step 2.
Check Mast Cable (1).
If Mast Cable (1) is disconnected, reconnect Mast Cable (1).
If Mast Cable (1) is defective, replace Mast Cable (1) (Para 4-31).
Step 3.
Check Remote Interface Box Mast Fuse (2).
If Remote Interface Box Mast Fuse (2) is defective, replace Remote Interface Box
Mast Fuse (2).
Step 4.
Ensure EM2E-24 Electric Mast (3) is enabled in Setup Parameters.