TM 5-6675-348-13&P
NOTE
When SET HEIGHT ALARM is selected, ARE YOU SURE? window appears. Selecting NO
disables HEIGHT ALARM and Bucket-ProTM System returns to CUSTOMIZE. Selecting
YES allows setting new HEIGHT ALARM.
(6)
Press ENTER button to confirm selection.
(7)
Press MODE button to access MAIN MENU.
Point menu arrows to CUSTOMIZE using Up and Down (↑↓) buttons.
(8)
(9)
Press ENTER button to confirm selection.
(10) Point menu arrows to SET LIMIT ALARMS, using Up and Down (↑↓) buttons.
NOTE
SET LIMIT ALARMS window appears.
LIMIT ALARMS window gives only choice of SET HEIGHT ALARM.
(11) Press ENTER button to confirm selection.
NOTE
When SET HEIGHT ALARM is selected,
ARE YOU SURE? window appears.
Selecting NO disables HEIGHT ALARM
and Bucket-ProTM System returns to
CUSTOMIZE. Selecting YES allows setting
new HEIGHT ALARM.
(12) Press ENTER button to confirm selection.
NOTE
HEIGHT ALARM can be set two ways. If
HYEX is moved before setting a number,
Bucket-ProTM System uses current
real-time data from the Angle Sensors to
set the alarm height. The height displayed
is either the bucket height or the dipper
stick pivot-pin height, whichever is highest.
If a button is pressed before any HYEX
movement is detected by the Angle Sensors,
Bucket-ProTM System assumes the manual
HEIGHT ALARM value is going to be
entered and ignores Angle Sensors inputs.
(13) Manually select height value you want
using Up and Down (↑↓) buttons.
(14) Press ENTER button to confirm selection.
(15) To exit the menu, press Up and Down (↑↓)
buttons to highlight EXIT and press
ENTER button, or press MODE button.
4-26