TM 5-6675-348-13&P
Unsafe welding practices can cause serious injury from fire, explosions, or harmful agents.
Allow only authorized personnel to weld or cut metals, and follow safety precautions in
TC 9-237. Protective clothing and goggles must be worn, adequate protective equipment
must be used, a suitable fire extinguisher must be kept nearby, and requirements of
TC 9-237 must be strictly followed. Failure to comply may result in serious injury or death
to personnel.
NOTE
For proper arm sensor calibration, weld within the lower lip of the Arm Sensor Mounting
Ring.
(8)
Weld Arm Sensor Mounting Ring (4) to Arm (2).
(9)
Paint Arm Sensor Mounting Ring (4) with black spray paint.
(10) Connect 40-ft Arm Sensor Cable (5) to
Arm Sensor (6).
(11) Install loop clamp (7) on 40-ft Arm
Sensor Cable (5).
NOTE
The Front Arm Sensor mount bolt
is also used to attach the loop
clamp.
The flat washer is not installed
with the loop clamp.
(12) Install Arm Sensor (6) to Arm Sensor
Mounting Ring (4) with three bolts (8),
and one loop clamp (7).
4-41