TM 5-6675-348-13&P
NOTE
For proper fitting and calibration, place Encoder Mounting Bracket's welded bracket tightly
against the factory weld inside the Arm.
(18) Using the Encoder Mounting Bracket (30), mark position of Encoder Mounting Bracket's welded
bracket (31), 2 in. (5.1 cm) down from Bucket Valve Adapter Plates and 0.75 in. (2 cm) in from left
side rail.
Unsafe welding practices can cause serious injury from fire, explosions, or harmful agents.
Allow only authorized personnel to weld or cut metals, and follow safety precautions in
TC 9-237. Protective clothing and goggles must be worn, adequate protective equipment
must be used, a suitable fire extinguisher must be kept nearby, and requirements of
TC 9-237 must be strictly followed. Failure to comply may result in serious injury or death
to personnel.
Do not weld across Arm. All welds must run parallel with the Arm. Failure to comply can
cause damage to the Arm.
(19) Weld Encoder Mounting Bracket's welded bracket (31) to Arm (2).
4-46