TM 5-6675-348-13&P
NOTE
At this point, the blade needs to be
which side (left or right) of blade is
going to be calibrated first. Side
shift blade to opposite side, then
move both cylinders to center of
ram.
If VALVE TEST appears in
windows, repeat Step (5).
VALVE CALIBRATE will flash
three times across windows (4) and
SET ALL will appear in left
window.
(6)
Select which side control valve will be
calibrated first. To enter into this
menu, press left or right RESET
button (5) for side you want to
calibrate.
NOTE
This should be the same side that
is side-shifted all the way to one
side.
↑ LIMIT should be displayed in the
left window.
(7)
Set upper limit, using blade's
R/L Switch (6), on side
to be calibrated, to lift blade
until cylinder is almost fully
retracted.
(8)
Press RESET button (5) for side to be
calibrated. AVERAGING SENSORS will
flash across windows (4).
3-31