b. Remove.
To avoid injury to personnel, ensure 130G Grader is shut off and blade is on the ground.
NOTE
Note location and placement of components prior to removal. This will aid in installation.
(1)
Remove 6-pin connector (1) and 8-socket
connector (2) from Operator Interface Box (3).
(2)
Place 6-pin connector (1) and 8-socket
connector (2) onto Connector Holders (4) located
on mounting bracket (5).
(3)
Loosen knob (6) on back of Operator Interface
Box (3) holding it to mounting bracket (5).
Remove Operator Interface Box (3).
(4)
Remove Blade Slope Sensor Cable (7) from Blade
Slope Sensor (8) and secure to Connector
Holder (9).
(5)
Remove two socket head screws (10) and Blade
Slope Sensor (8) located in pocket (11) of
130G Grader's Rotation Circle (12).
NOTE
Socket head screws are used to protect
the threads of the Slope Sensor Plate.
(6)
Install two socket head screws (13) in Slope
Sensor Plate (14).