TM 5-6675-348-13&P
To ensure proper Blade-Pro Motor
Grader Control System operation,
ensure all sensor plates are clean and
free of debris before bolting any
sensors down.
(7)
Install Mainfall Slope Sensor (16),
located on right side of the
130G Grader's Gooseneck (19), on
Mainfall Slope Sensor Mounting
Plate (21) with two socket head
screws (18).
(8)
Tighten socket head screws (18).
To avoid damage to equipment,
ensure cable connector is clean
and dry.
(9)
Install Mainfall Slope Sensor Cable (15)
on Mainfall Sensor (16).
(10) Remove Blade Slope Sensor Cable (7) from
Connector Holder (9).
(11) Remove two socket head screws (13) from
Slope Sensor Plate (14).
(12) Install Blade Slope Sensor (8) in
pocket (11) of 130G Grader's Rotation
Circle (12) with two socket head
screws (10).
(13) Tighten socket head screws (10).
(14) Install Blade Slope Sensor Cable (7) on
Blade Slope Sensor (8).
3-39