TM 5-6675-348-13&P
(44) Cable tie Main Power Cable (38) to Operator
Cable (36).7
NOTE
Leave approximately 18 in. (46 cm) of both
cables outside front of Gooseneck.
(45) With the aid of an assistant, pull Operator
Cable (36) until both Main Power Cable (38)
and Operator Cable (36) are hanging through
front and rear of Gooseneck (27).
Hydraulic oil is slippery and can cause
falls. To avoid injury, wipe up all spilled
hydraulic oil with rags.
NOTE
Inspect all hoses, lines, and fittings for
cracks, bends, nicks, dents, stripped
threads, and cuts. Replace all damaged
parts.
Tag and mark all existing lines prior
to removal.
Plug holes and cap fittings to prevent
oil spills.
Retain 90-degree fittings and T-fittings
for installation of Proportional Valve.
(46) Remove two Float Valve Lines (35), Cylinder
Lines (39), T-fittings (40), and 90-degree
fittings (41) from left Lift and Articulation
Check Valve (LACV) (42).
3-94