TM 5-6675-348-13&P
Failure to replace Hydraswivel Gaskets and Hydraswivel Shims in original positions may
cause leakage or damage to equipment.
(6)
Install Hydraswivel Gaskets (4) and (5) into Orientation Disc (7).
(7)
Install Hydraswivel Shims (6) under Orientation Disc (7).
(8)
Install Orientation Disc (7) to Hydraswivel (3) with Milled Slot (8) positioned toward rear of
130G Grader.
(9)
Install two screws (1) in Orientation Disc (7).
(10) Tighten screws (1).
(11) Install Teflon Ring (9) on Circle Rotation Sensor (10).
(12) Line up Dog Bone (11) with Milled Slot (8) in Orientation Disc (7).
NOTE
For ease of calibration, place 2-pin female connector of Circle Rotation Sensor toward rear of
130G Grader.
(13) Install Circle Rotation Sensor (10) onto Orientation Disc (7).
3-89