BUCKET-PROTM SYSTEM CALIBRATION. - Continued
BUCKET-PROTM SYSTEM CALIBRATION. - Continued

Laser Leveling Equipment (Lle) For Graders, Dozers, & Scrapers Page Navigation
  222    223    224    225    226  227  228    229    230    231    232  
img
TM 5-6675-348-13&P
d.
Boom Angle Calibration.
NOTE
Before performing boom angle calibration, ensure that system setup has been completed.
(1)
In SETUP menu, select CALIBRATION, using Up and
Down (↑↓) buttons.
(2)
Press ENTER button.
(3)
In CALIBRATION menu, select BOOM ANGLE, using Up and
Down (↑↓) buttons.
NOTE
Boom sensor is correctly indexed when
sensors index mark (?) changes to sensor
index mark (I) on Graphic Display.
(4)
Move boom (1) through a range of motion
to ensure boom sensor is indexed.
(5)
Using an Automated Integrated Survey
Instrument (AISI), position boom pivot
pin (2) horizontally level with arm pivot
pin (3).
(6)
Press ENTER button.
4-68