TM 5-6675-348-13&P
NOTE
The BOOM ANGLE number is used
during troubleshooting.
(7)
Record BOOM ANGLE number.
(8)
In the ARE YOU SURE? dialog box, select YES, using the Up
and Down (↑↓) buttons, and update data.
e.
Arm Angle Calibration.
NOTE
ensure that system setup has been
completed.
(1)
and Down (↑↓) buttons.
(2)
Press ENTER button.
(3)
In CALIBRATION menu, select ARM ANGLE, using
the Up and Down (↑↓) buttons.
NOTE
Arm sensor is correctly indexed when
sensor index mark (?) changes to sensor
index mark (I) on Graphic Display.
(4)
Move arm (4) through a range of motion
to ensure arm sensor is indexed.
(5)
Using an AISI, position arm pivot pin (3)
directly vertical over bucket pivot pin (5).
4-69