BUCKET-PROTM SYSTEM CALIBRATION. - Continued
BUCKET-PROTM SYSTEM CALIBRATION. - Continued

Laser Leveling Equipment (Lle) For Graders, Dozers, & Scrapers Page Navigation
  224    225    226    227    228  229  230    231    232    233    234  
img
TM 5-6675-348-13&P
(6)
Press ENTER button.
NOTE
The ARM ANGLE number is used
during troublshooting.
(7)
Record ARM ANGLE number.
(8)
In the ARE YOU SURE? dialog box, select YES, using the Up
and Down (↑↓) buttons, and update data.
f.
Bucket Cylinder Calibration.
Do not strike cylinder against end stops
when retracting and extending, or damage
to equipment may result.
NOTE
Bucket cylinder calibration divides bucket
cylinder length into increments and linkage
measurements to calculate rotated position
of bucket teeth.
(1)
Perform smooth extend and retract
movements of bucket cylinder (6).