TM 5-6675-348-13&P
Remove all jewelry, such as rings, dog tags, bracelets, etc. If jewelry contacts Battery
Terminal, a direct short may result in instant heating of tools, damage to equipment,
and injury or death to personnel.
Exercise extreme caution when working under tilt platform. Falling platform could
result in serious injury or death to personnel.
Turn battery disconnect switch OFF prior to performing maintenance in immediate
battery area or working on electrical system. Failure to comply can result in electrical
shock to personnel or damage to equipment.
To avoid damage to Power Cable, it must be routed through Articulation Joint (following
existing electrical cables and hoses).
NOTE
Cable tie as needed.
(159) Route Main Power Cable (38) under cab, through Articulation Joint, and up through hole under
Engine Compartment (122).
3-111