• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 3-5. Blade Pro Motor Grader Control System PMCS (Quarterly)
Circle Rotation Sensor Calibration.

Laser Leveling Equipment (Lle) For Graders, Dozers, & Scrapers Page Navigation
  53    54    55    56    57  58  59    60    61    62    63  
img
. . .
TM 5-6675-348-13&P
SECTION III. BLADE PRO MOTOR GRADER CONTROL SYSTEM OPERATION
BLADE PRO MOTOR GRADER CONTROL SYSTEM GENERAL INFORMATION.
3-14.
Operator Interface Box Controls and Indicators.
1. Display Window.
2. Above-Grade Indicator (2) (Yellow)
3. On-Grade Indicator (2) (Green)
4. Below-Grade Indicator (2) (Yellow)
5. Mode Switch
6. Slope Switch
7. ON/OFF/SET-UP Switch
8. RESET Button (2)
9. Increase/Decrease Switch (2)
10. Manual LED (2) (Red)
11. Automatic LED (2) (Green)
12. Quick Instruction Cards
BLADE PRO MOTOR GRADER CONTROL SYSTEM SENSOR CALIBRATION.
3-15.
NOTE
Sensor calibration requires the aid of an assistant.
Valve calibration and sensor calibration settings are specific for the make, model,
bumper number, and serial number once calibration is completed.
a.
Circle Rotation Sensor Calibration.
(1)
Rotate and align chisel marks on 130G Grader's Rotation Circle to draw bar reference.
(2)
Place cutting edge firmly on ground.
(3)
Loosen two bolts (1) on Rotation
Sensor (1.1).
3-22