TM 5-6675-348-13&P
Table 3-4. Blade Pro Motor Grader Control System Operator's PMCS (Before/After) (Cont)
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/Service
Procedure
Capable If:
5.
Before/After Remote
Interface Box
To avoid damage to equipment,
fuse must be replaced with
25-amp fuse.
Check 25-amp fuses to ensure they are
Fuse is blown. Replace
not burned out.
before operating.
Dirt, debris, and/or
Check left and right socket connectors
damaged connectors are
for any dirt, debris, or damaged
present.
connections.
Nuts or screws are loose.
Check nuts and screws for tightness.
6.
Before/After Mainfall Slope
Check electrical connectors for any
Connectors are damaged.
Sensor and
dirt, debris, or damage.
Blade Slope
Sensors
7.
Before/After Circle Rotation
Check electrical connectors for dirt,
Connectors are damaged.
Sensor
debris, or damage.
Check screws for tightness.
8.
Before/After Tracer Sonic
Check electrical connectors and
Connectors are damaged.
Grade
transducer for dirt, debris, or damage.
Transducer is soiled,
Controller
dented, or foil inside is
Wipe dirt and dust from housing covers
ripped.
with damp cloth. Inspect exterior for
damage or cracks.
Wipe dirt and dust from transducer,
using soft cloth or low-pressure air.
9.
Before/After R2S-S Laser
Check electrical connections for dirt,
Connectors are damaged.
Receiver
debris, or damage.
Wipe dirt and dust from metal housing
cover with damp cloth.
Inspect windows for cracks and ensure
Windows are cracked or
black dust seal is still in place.
black dust seal is missing.
Clean windows with clean water or
general purpose cleaner and soft cloth.
Check and clean breather hole.
Breather hole is plugged.
3-20