TM 5-6675-348-13&P
(1)
Left-Side Connections.
(a)
10-Socket (Left Elevation Input)
(b)
3-Socket (Load Sensing Valve)
(c)
4-Socket (Blade Rotation, and Blade
Slope Sensors)
(d)
5-Socket (Mainfall Slope Sensors)
(e)
7-Socket (Left Hydraulic Valve)
(2)
Right-Side Connections.
(a)
10-Socket (Right Elevation Input)
(b)
8-Socket (Operator Interface Box)
(c)
4-Pin (System Power)
(d)
7-Socket (Right Hydraulic Valve)
(e)
Overload Protection (Fuse)
Table 3-2. Blade Pro Motor Grader Control System Operator Interface Box Controls
Key
Controls or
Function
Indicator
1. OFF/ON/SET-UP:
In left position
System is OFF.
In center position System is ON.
In right position
Operator has access to the following SET-UP functions:
Elevation Reference, Customize, Test, Slope Speed, and
Elevation Speed. (For more information on SET-UP
options, refer to Section III)