TM 5-6675-348-13&P
Remote Interface Box. Central controller and
a.
processor for all sensors, inputs, and elevation
devices. Output signals are provided to the
control valves and the Operator Interface Box.
Operator Interface Box. Located in front of the
b.
Operator; provides easy access to all Blade Pro
Motor Grader Control System control functions.
(1)
The operating status is indicated with
Light-Emitting Diodes (LEDs) (2) and (3),
which indicate the operating status of the
right and left sides.
Green (2) Indicator
Automatic
Operation
Red (3) Indicator
Manual Operation
Solid Green (2) with Flashing Red (3)
Inactive Automatic
(2)
The Operator Interface Box uses bright
LEDs to indicate the blade's position relative
to the desired grade. Operation status
windows (7) use a back-lighted Liquid
Crystal Display (LCD) to indicate
percent (%) slope, direction of slope,
elevation, and error messages. Customized
functions and features can also be displayed
when in SETUP mode.
3-7