TM 5-6675-348-13&P
(4)
Pull Operator Interface Box (4) up from
mounting bracket (5).
(5)
Attach loose connectors (1) and (3) to
provided dust covers (6) and (7) on side of the mounting bracket (5).
c.
Operator Interface Box Viewing Angle Adjustment.
(1)
Loosen mounting knob (2) on back of Operator Interface Box (4).
(2)
Rotate Operator Interface Box (4) for best viewing angle, then tighten mounting knob (2).
BLADE PRO MOTOR GRADER CONTROL SYSTEM SPECIFICATIONS.
Blade Slope Sensor Resolution
0.01% slope
Mainfall Slope Sensor Resolution
0.01% slope
Circle Rotation Sensor Resolution
0.1 degree
Articulation Sensor Resolution
0.1 degree
Cross-Slope Resolution
0.01% slope
*Cross-Slope Accuracy
1/4 in./10 feet
Cross-Slope Range
19.99%
* System accuracy is affected by the tightness of the machine. (Refer to Para 3-23 for more
information about determining the machine's slope.)