Table 3-2. Blade Pro Motor Grader Control System Operator Interface Box Controls (Cont)
BLADE PRO MOTOR GRADER CONTROL SYSTEM SPECIFICATIONS.

Laser Leveling Equipment (Lle) For Graders, Dozers, & Scrapers Page Navigation
  44    45    46    47    48  49  50    51    52    53    54  
img
. . .
TM 5-6675-348-13&P
Table 3-2. Blade Pro Motor Grader Control System Operator Interface Box Controls (Cont)
Key
Controls or
Function
Indicator
5. RIGHT/LEFT (R/L)
Provides remote switching of the system from automatic to
SWITCH:
manual operation at the manual control levers.
6. RESET SWITCH:
Resets Tracer Sonic Grader Controller reference to a new
surface or object.
7. REMOTE SWITCH:
Function of the switch is selected in SETUP mode.
Options include Elevation Offsets, Slope Offsets, and Auto
Raise/Lower. (For further details on these options, refer to
Para 3-23)
BLADE PRO MOTOR GRADER CONTROL SYSTEM MOUNTING AND ADJUSTMENTS.
3-4.
a.
Operator Interface Box.
(1)
Serial Communication Connector
(2)
Mounting Knob
(3)
Remote Switch Connector
b. Operator Interface Box Removal.
(1)
Disconnect Remote Switch Connector (3) from back
of Operator Interface Box (4).
(2)
Disconnect Serial Communication Connector (1)
from back of Operator Interface Box (4).
(3)
Loosen mounting knob (2) on back of Operator Interface Box (4).
3-13