Allow solder to cool before handling wire.
Failure to comply may result in injury to
personnel.
(21) Solder two connections (24) to Red Wire (25)
and Black Wire (26).
(22) Remove two nuts (27).
(23) Install Red Wire (25) on Positive (+) Battery
Terminal (28).
(24) Install Black Wire (26) on Negative (-) Battery
Terminal (29).
(25) Install and tighten nuts (27).
(26) Drill one 1/2-in. (13 mm) hole (30) in lower left
corner of Battery Box (23), approximately
1 in. (2.54 cm) from side and 4 in. (10 cm) from
bottom.