(95) Install Power Cable's positive (red)
wire (108) on positive Battery Terminal
Clamp (109) with washer (110),
lockwasher (111), and nut (112).
(96) Tighten nut (112).
(97) Coil excess Voltage Protection Cable (103)
in Battery Box (102).
(98) Install Power Cable's negative (black)
wire (113) and Voltage Protection
Cable (103) on negative Battery Terminal
Clamp (109) with washer (110),
lockwasher (111), and nut (112).
(99) Tighten nut (112).
(100) Coil excess Voltage Protection Cable (103)
in Battery Box (102).
(101) Install Power Cable (107), Boom
Sensor Cable (25), Arm Sensor
Cable (5), Encoder Cable (42), Mast
Cable (94), Display Cable (77), and
Dual-Axis Tilt Sensor Cable (86), on
Remote Interface Box (51).