TM 5-6675-348-13&P
(89) Relocate radiator over flow tube (99) to
other side of Bracket (100).
CARC paint contains isocyanate
(HDI), which is highly irritating to
skin and respiratory system. High
concentrations of HDI can produce
symptoms of itching and reddening
of skin, a burning sensation in
throat and nose, and watering of
the eyes. In extreme concentra-
tions, HDI can cause cough, short-
ness of breath, pain during
respiration, increased sputum pro-
duction, and chest tightness. The
following precautions must be
taken whenever using CARC paint:
ALWAYS use air line respirators when using CARC paint, unless air sampling shows
exposure to be below standards. Use chemical cartridge respirator if air sampling is
below standards.
DO NOT let skin or eyes come in contact with CARC paint. Always wear protective
equipment (gloves, ventilation mask, safety goggles, etc.).
DO NOT use CARC paint without adequate ventilation.
NEVER weld or cut CARC-coated materials.
DO NOT grind or sand painted equipment without high-efficiency air purifying
respirators in use.
BE AWARE of CARC paint exposure symptoms; symptoms can occur a few days after
initial exposure. Seek medical help immediately if symptoms are detected.
(90) Clean paint and material from hole (101) in
Battery Box (102) using wire brush.
(91) Install Voltage Protection Cable (103) in
hole (101) with lockwasher (104),
washer (105), and nut (106).
(92) Tighten nut (106).
(93) Paint hole (101) with black spray paint.
(94) Route Power Cable (107) to Battery
Box (102).
4-59