TM 5-6675-348-13&P
Table 3-10. Error-to-Source Relationships (Cont)
Abbreviation
Level 3 Errors
Error #
Articulation angle signal value too high with sensor ON.
Articulation
Articulation Angle Sensor or cable.
High
21
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Operator Interface Box serial transmission check sum fault detected.
Serial Check
Operator Interface Box.
Sum
Operator Interface Box cable.
22
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Operator Interface Box serial transmission ID number out of range detected. Serial ID
Operator Interface Box.
Operator Interface Box cable.
23
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Operator Interface Box serial transmission incomplete packet detected.
Serial Packet
Operator Interface Box.
Operator Interface Box cable.
24
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Operator Interface Box serial transmission framing fault detected.
Serial Frame
Operator Interface Box.
Operator Interface Box cable.
25
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Operator Interface Box serial transmission noise detected.
Serial Noise
Operator Interface Box.
Operator Interface Box cable.
26
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Operator Interface Box serial transmission overrun detected.
Serial
27
Remote Interface Box CPU board.
Overrun
Abbreviation
Level 4 Errors
Error #
Left fine lower valve voltage incorrect.
Left Lower
Remote Interface Box CPU board.
Fine
Remote Interface Box motherboard.
28
Remote Interface Box left driver board.
Left fine lower valve or cable.
Left medium lower valve voltage incorrect.
Left Lower
Remote Interface Box CPU board.
Medium
Remote Interface Box motherboard.
29
Remote Interface Box left driver board.
Left medium lower valve or cable.
3-76