TM 5-6675-348-13&P
Level 1 Errors
Abbreviation
Error #
Blade On
Blade slope signal detected with sensor OFF.
1
User turned OFF Blade Slope Sensor but did not disconnect it.
Remote Interface Box CPU board.
Mainfall signal detected with sensor OFF.
Mainfall On
User turned OFF Mainfall Slope Sensor but did not disconnect it.
2
Remote Interface Box CPU board.
Rotation angle signal detected with sensor OFF.
Rotation On
User turned OFF rotation Angle Sensor but did not disconnect it.
3
Remote Interface Box CPU board.
Articulation angle signal detected with sensor OFF.
Articulation
User turned OFF articulation Angle Sensor but did not disconnect it.
On
4
Remote Interface Box CPU board.
Error #
Abbreviation
Level 2 Errors
Valve type not selected.
No Valve
User did not yet select a valve type.
Selected
5
Remote Interface Box CPU board.
Blade slope signal frequency too low or stopped with sensor ON.
Blade Slow
Blade Slope Sensor or cable.
6
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Blade slope signal frequency too high with sensor ON.
Blade Fast
Blade Slope Sensor or cable.
7
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Blade slope signal value too low with sensor ON.
Blade Low
Blade Slope Sensor or cable.
8
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Blade slope signal value too high with sensor ON.
Blade High
Blade Slope Sensor or cable.
9
Remote Interface Box CPU board.
Remote Interface Box motherboard.
Mainfall signal frequency too low or stopped with sensor ON.
Mainfall Slow
Mainfall Slope Sensor or cable.
10
Remote Interface Box CPU board.
Remote Interface Box motherboard.