TM 5-6675-348-13&P
SECTION VI. BLADE PRO MOTOR GRADER CONTROL SYSTEM ERROR LOG
Level 1 Errors
Display Messages
Blade slope signal detected with sensor OFF.
BLADE OFF
Mainfall signal detected with sensor OFF.
MAINFALL OFF
Rotation angle signal detected with sensor OFF.
ROTATION OFF
Articulation angle signal detected with sensor OFF.
ART. OFF
Level 2 Errors
Display Messages
Valve type not selected.
VALVE OFF
Blade slope signal frequency too low with sensor ON.
BLADE FAULT
Blade slope signal frequency too high with sensor ON.
BLADE FAULT
Blade slope signal value too low with sensor ON.
BLADEČ RANGE
Blade slope signal value too high with sensor ON.
BLADEČ RANGE
Mainfall signal frequency too low with sensor ON.
MAINFALL FAULT
Mainfall signal frequency too high with sensor ON.
MAINFALL FAULT
Mainfall signal value too low with sensor ON.
MAINFALLČ RANGE
Mainfall signal value too high with sensor ON.
MAINFALLČ RANGE
Rotation angle signal frequency too low with sensor ON.
ROTATION FAULT
Rotation angle signal frequency too high with sensor ON.
ROTATION FAULT
Rotation angle signal value too low with sensor ON.
ROTATIONČ RANGE
Rotation angle signal value too high with sensor ON.
ROTATIONČ RANGE
Articulation angle signal frequency too low with sensor ON.
ART. FAULT
Articulation angle signal frequency too high with sensor ON.
ART. FAULT
Articulation angle signal value too low with sensor ON.
ART.Č RANGE
Articulation angle signal value too high with sensor ON.
ART.Č RANGE
Level 3 Errors
Display Messages
Operator Interface Box serial transmission check sum fault detected.
SERIAL ERROR
Operator Interface Box serial transmission bad ID number detected.
SERIAL ERROR
Operator Interface Box serial transmission incomplete packet
SERIAL ERROR
detected.
Operator Interface Box serial transmission framing fault detected.
SERIAL ERROR
Operator Interface Box serial transmission noise detected.
SERIAL ERROR
Operator Interface Box serial transmission overrun detected.
SERIAL ERROR