Table 3-7. Blade Pro Motor Grader Control System Troubleshooting - Continued
Table 3-7. Blade Pro Motor Grader Control System Troubleshooting - Continued

Laser Leveling Equipment (Lle) For Graders, Dozers, & Scrapers Page Navigation
  96    97    98    99    100  101  102    103    104    105    106  
img
. . . .
TM 5-6675-348-13&P
Table 3-7. Blade Pro Motor Grader Control System Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
FAULT 3-6. CROSS-SLOPE SIDE DOES NOT CUT DESIRED SLOPE.
Step 1.
The 130G Grader (1) may not be able to cut material at the depth you are trying to cut.
Try making several passes to remove material.
Step 2.
The 130G Grader (1) may need to be calibrated.
Perform full calibration (Para 3-15 and Para 3-16).
NOTE
Excessive 130G Grader mechanical wear can give the Blade Pro Motor Grader Control
System false sensor readings.
Step 3.
Check 130G Grader (1) for excessive mechanical wear.
Inspect 130G Grader (1) for wear (Section VII).
3-65