TM 5-6675-348-13&P
GRADIO DISPLAY SYSTEM TROUBLESHOOTING INSTRUCTIONS.
Malfunction
Test or Inspection
Corrective Action
FAULT 2-1. GRADIO DISPLAY SYSTEM DOES NOT OPERATE.
Step 1.
Ensure 1145-2 Laser Transmitter is correctly set up and operating
If 1145-2 Laser Transmitter is correctly set up and operating, go to Step 2.
If 1145-2 Laser Transmitter is not correctly set up and operating, go to Chapter 5.
Step 2.
Check bright/dim switch (1) on DR2 Display for proper position.
If bright/dim switch is in wrong position, move switch to correct position.
If bright/dim switch is damaged or faulty, return switch to manufacturer.
Dash number on back of RT2S Laser Receiver must match dash number on the DR2
Display. If dash numbers are not the same, the equipment will fail to operate.
Step 3.
Check RT2S Laser Receiver ON/OFF switch (2) and channel compatibility with
DR2 Display.
If dash numbers are not the same, replace with compatible parts.