TM 5-6675-348-13&P
(2)
Beeper < (Cross-Slope). Two short beeps are emitted when cross-slope-controlled side of blade
remains in a fine correction for more than 2 seconds. If a medium or coarse correction signal is
indicated, two short beeps are emitted with no delay. This alerts the Operator that the slope has
not been cut correctly. A second pass or ripping the material may be required to cut to grade.
Slope. % Slope or Rise/Run Display. Allows the Operator to select how cross-slope is displayed in
e.
display window. Options are percent slope (5) or rise/run (e.g., 1/4 in. per foot (6 mm per meter) is
displayed as 1/4" in English; 6 mm per meter is displayed as 6 mm/m metric).
Test. Activates all LCD segments and LED indicator lights. Visual display shows any missing LCD
f.
segments or burned-out LED indicators. The test feature also displays errors that may have occurred.
PROGRAMMING BLADE PRO MOTOR GRADER CONTROL SYSTEM USER OPTIONS.
a.
General Information.
NOTE
SET-UP can be exited from any point in the SET-UP menu by positioning the OFF/ON/SET-
UP switch back to the ON position.
(1)
Switches used in SET-UP Mode.
(a)
To enter SET-UP, position the OFF/ON/
SET-UP switch (1) to SET-UP position.
NOTE
Left Increase/Decrease switch controls
the menu displayed in left display
window.
(b)
Toggle left Increase/Decrease switch (2)
down to move next item in menu.
(c)
Toggle left Increase/Decrease switch (2) up to move back to last displayed item.
(d)
Use left RESET Button (3) to enter or exit selected menu displayed in left display window.
(e)
Right Increase/Decrease switch (4) changes feature from ON to OFF or value displayed in
right window (for example: ON to OFF or 1.25 to 1.26).
(f)
SET-UP can be exited from any point in the SET-UP menu by positioning the
OFF/ON/SET-UP switch (1) back to the ON position.