TM 5-6675-348-13&P
(4)
To enter a different reference elevation
into both the left and right windows:
(a)
Position Mode switch (1) to left
position.
Left Display
Right Display
+ 0.00
< 1.9%
(b)
Position OFF/ON/SET-UP
switch (2) to SET-UP position.
Left Display
Right Display
REFERENCE
0.00
(c)
Use right Increase/Decrease
switch (3) to change elevation value
in right display window for desired
reference elevation for left side of
blade.
Left Display
Right Display
REFERENCE
1.25
(d)
Position OFF/ON/SET-UP
switch (2) back to ON position.
Left Display
Right Display
+ 1.25
< 1.9%
3-52