b. Tabulated Data.
column, a target level and the target pattern
which includes a centering mark.
(1) G e n e r a l .
Manufacturer _ _ _ _ _ _ _ _ _ _Wild Heerbrugg, Ltd.
Model _ _ _ _ _ _ _ _ _ _ _ _ _ _ _T-2
illumination assembly is used for night work
Contract No. _ _ _ _ _ _ _ _DA-11-184-AMC-504 (T)
and consists of a lamp and cable. This assembly
(2) Dimensions and weight.
is attached to a reflector mounted behind the
Length _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _12 in. (inch)
Width _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 11 in.
nation assembly is powered by the battery case
Height _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 in.
which is attached to the tripod.
Weight_ _ _ _ _ _ _ _ _ _ _ _ _ _ 12 lb (pound)
4. Identification and Tabulated Data
This manual covers the Surveying Target
a. Identification. The surveying target set
Set, Wild Heerbrugg Model T-2 only. No
has no identification plates. The tabulated data
known unit differences exist for the model
for the surveying target set can be found in
covered by this manual.
tabulated data (b below).
AGO 10139A