TM 5-6675-348-13&P
Table 5-3. 1145-2 Laser Transmitter Troubleshooting (Cont)
Malfunction
Test or Inpsection
Corrective Action
FAULT 5-2. LASER BEAM WILL NOT SHUT OFF WHEN 1145-2 LASER
Step 1.
Ensure Control Switch (1) is in AUTO position.
FAULT 5-3. 1145-2 LASER TRANSMITTER LOW VOLTAGE INDICATOR LAMP IS ON.
Connecting to 24 Vdc will damage laser. Ensure external power is 12 Vdc. Failure to
comply will result in damage to equipment
Step 1.
Charge internal Battery using Power/Charge Connector (1).
Step 2.
Verify sufficient charge in your external 12-Vdc battery (2).
Step 3.
Check Power/Charge Connector (1) for dirt.
If Power/Charge Connector (1) is dirty, clean with clean cloth.
Step 4.
Ensure twist-lock ring on Power Cord (3) is snapped in place.
Step 5.
Check for a broken or frayed wire in Power Cord (3), particularly at receptacle end.