TM 5-6675-348-13&P
Unsafe welding practices can cause serious
injury from fire, explosions, or harmful
agents. Allow only authorized personnel to
weld or cut metals, and follow safety precau-
tions in TC 9-237. Protective clothing and
goggles must be worn, adequate protective
equipment must be used, a suitable fire
extinguisher must be kept nearby, and
requirements of TC 9-237 must be strictly
followed. Failure to comply may result in
serious injury or death to personnel.
(194) Weld front and back of Slope Sensor
Mounting Plate (152) to Frame Pocket (153).
(195) Position and weld Connector Holder (156) to
Frame Pocket (153).
To prevent damage to the Slope Sensor
Cable, allow enough slack in Slope Sensor
Cable at Circle Rotation Sensor connection
to permit circle movement.
NOTE
Allow enough slack at Slope Sensor
Connector to reach Blade Slope Sensor.
(196) Install Slope Sensor Cable (157) to
Connector Holder (156).
NOTE
Allow enough slack in the Slope Sensor
Cable to allow for rotation of the Circle
Frame.
(197) Route Slope Sensor Cable (157) along
hydraulic lines on top of Hose Tray (158),
to Circle Rotation Sensor (10).
(198) Connect Slope Sensor Cable (157) to
Circle Rotation Sensor (10).
(199) Cable tie as needed.
3-120