Operation in Dusty or Sandy Areas
Section III. TROUBLESHOOTING

Detecting Set, Mine: Aural Indication; 10V Dc Operating Power: Portable Transistorized, W/Case Page Navigation
  10    11    12    13    14  15  16    17    18    19    20  
img
. . . . . . . . . . . . . . . . .
TM 5-6665-202-13
CHAPTER 3
OPERATOR/CREW MAINTENANCE INSTRUCTIONS
Section I. LUBRICATION lNSTRUCTlONS
No lubrication of the mine detector set will be performed by the operator/crew personnel.
Section Il. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
is noted during operation which would damage
3 - 1 . General
the equipment if operation were continued. All
To insure that the mine detecting set is ready
for operation at all times, it must be inspected
deficiencies and shortcomings will be recorded
systematically so that defects may be discovered
together with the corrective action taken cm form
and corrected before they result in serious dam-
2404 at the earliest possible opportunity.
age or failure. The necessary preventive mainte-
nance checks and services to be performed are
3-2. Preventive Maintenance Checks and
listed as described in table 3-1. The item num-
Services
bers indicate the sequence of minimum inspec-
tion requirements. Defects discovered during op-
Refer to table 3-1 and perform the daily preven-
eration of the unit will be noted for future cor-
tive maintenance checks and services. If equip
rection to be made as soon as operation has
ment is not in use, perform maintenance checks
ceased. Stop operation immediately if a deficiency
and services on a weekly basis.
Table 3-1. Preventive Maintenance Checks and Services
Daily Schedule (or weekly)
Operator Maintenance Category
3-1