TM 10-4510-206-14
5-7.
REPAIR PROCEDURES (CONTD)
o.
Low Water Probe Assembly (Contd)
12.
Install electrode fitting (3) and condulet assembly (8)
by inserting electrode fitting (9) in water heater and turning
clockwise.
13.
With pipewrench turn condulet (8) clockwise until it mates with
conduit nut (4).
14.
Tighten nut (4).
5-84