TM 10-4510-206-14
2.-7.1.
PRELIMINARY SERVICING AND ADJUSTMENTS OF EQUIPMENT
CAUTION
Perform this procedure whenever the Bath Unit is set up
at a new location or whenever any maintenance to the
Bath Unit is done involving disconnection/reconnection
of electrical wiring.
Failure to do so could result in
damage to pump motors.
a.
Ensure power cable assembly is connected to a 208 vat, 3-phase, 60 Hz
power source.
b.
Note direction of arrow (1) on water pump motor (2).
c.
Quickly turn water pump switch (3) on and off, and immediately check
the rotation of the fins inside the motor.
The fins can be seen through the
motor casing (4)
d.
If the water pump is not rotating in the same direction as the arrow,
contact organizational maintenance to reverse any two of the leads at the motor
junction box (5) (paragraph 4-13d).
Change 4
2-16.1