TM 5-6675-348-13&P
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS.
BATTERY DOOR. Holds four alkaline,
(1)
C-size batteries.
ON/OFF SWITCH. Used to turn the
(2)
RT2S Laser Receiver ON and OFF.
12-/24-vdc bulbs may be used. To avoid
damage to equipment, ensure 24-v bulbs
are installed for 24-v electrical system
and 12-v bulbs are installed for
12-v electrical system.
(3)
RT2S LASER RECEIVER CLAMP.
"Universal" design allows RT2S Laser
Receiver to be mounted on 1 1/2-in. to
2-in. (3.81 cm to 5.1 cm) diameter round
tubing or 1 1/2-in. to 1 3/4-in. (3.81 cm to
4.45 cm) square tubing.
OVERLOAD PROTECTION. A 5-amp
(4)
fuse is used to protect the DR2 Display.
DISPLAY CONTROL SWITCH. Turns the
(5)
DR2 Display on in either bright or dim
DR2 Display mode for day or night use.
CHANNEL INDICATION. Designates
(6)
channel configuration of the RT2S
Laser Receiver or the DR2 Display. Channels must match for proper operation. Matching channels
have the same color heat shrink tubing on the antenna.
OPERATOR SETUP LAMPS. Light-emitting diodes (LED) on the back of the DR2 Display reflect
(7)
activity of the DR2 Display panel lights. This allows for one-soldier setup.
GRADE INDICATOR LAMPS. Used to communicate grade information to the Operator.
(8)
OUT-OF-BEAM INDICATOR. LEDs on the DR2 Display panel indicate which direction the
(9)