Figure 20. Horizontal, vertical, and collimation slow-motion screws, adjustment.
Figure 23. Horizontal collimation error, adjustment.

Theodolite; Directional 2/10 Sec, Degree Graduation 10.2-In. Long Telescope W/ Accessories Page Navigation
  21    22    23    24    25  26  27    28    29    30    31  
img
22. Operation in Salt Water Areas
Salt is highly corrosive to metals. When operating
the theodolite in salt water areas, wipe the instrument
frequently with a soft, clean cloth. If the theodolite is
exposed to direct salt spray, it should be cleaned
thoroughly and should be returned to an instrument shop
for overhauling as soon as possible. Cleaning intervals
should  be  shortened  considerably  for  theodolites
subjected to salt air exposure.
Figure 22. Leveling screws adjustment.
Figure 21. Horizontal circle drive, adjustment.
areas and desiccants.  After use, dry the instrument
thoroughly with a soft, lint-free cloth.