TM 10-4510-206-14
5-7.
REPAIR PROCEDURES (CONTD)
a.
Power Cable Assemblies (Contd)
5.
Slip cap cover (1) onto replacement cable (4) of same length and
trim wire ends to same length.
6. Cut outer insulation from cable 2-inches from end and trim
approximately 3/8-inch from tip of wire.
7.
Crimp terminal lugs (5) to end of five wires.
8.
Connect terminal lugs (5)
with wire colors keyed to
to connector using terminal screws (3)
connector terminals (6).
Change 4
5-7