TM 10-4510-206-14
Table 4-2.
Organizational Troubleshooting Procedures (Contd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
15.
WATER PUMP FAILS TO DELIVER WATER
Step 1.
Check to see if water pump motor runs.
Replace water pump motor.
Notify direct support maintenance.
Step 2.
Check water pump for reversed rotation.
Interchange any two of the external leads at the motor.
Step 3.
Check water pump shaft seals for leaks.
Replace water pump motor.
16.
WATER PUMP FAILS TO ROTATE
Step 1.
Check to see if electric motor is operating.
Tighten electrical connections.
Replace motor.
See paragraph 4-14.
17.
WATER PUMP ASSEMBLY NOISY
Step 1.
Check water pump assembly for
Replace water pump motor.
proper operation.
See paragraph 4-14.
18.
SHOWER STAND NOZZLES NOT DISCHARGING ENOUGH WATER
Step 1.
Check water flow control valves at shower nozzles to see if
they are closed or damaged.
Replace water flow
Step 2.
Check for shower stand
Replace fittings.
control valve.
closed or pinched fittings.
4-17