Table J-1. Torque Limits for Wet Flange Nuts
Table J-3. Torque Limits for Dry Fasteners

Laser Leveling Equipment (Lle) For Graders, Dozers, & Scrapers Page Navigation
  408    409    410    411    412  413  414    415    416    417    418  
img
TM 5-6675-348-13&P
Table J-2. Torque Limits for Wet Socket Head Capscrews (Continued)
0.56-12
106
53
0.62-11
212
106
0.75-10
375
187
1.00-8
781
b. Hoses and Fittings.
NOTE
Most fluid piping system sizes are
measured by dash numbers. These are
universally used abbreviations for the
size of the component expressed at the
numerator of the fraction with the
denominator always being 16. For
example, a -04 port is 4/16 or 1/4 inch.
Dash numbers are usually nominal (in
name only) and are abbreviations that
make ordering of components easier.
(1)
Measure the I.D./O.D. with a caliper as
shown.
(2)
Under the heading MALE THREAD O.D.
and FEMALE THREAD I.D., match the
measurements with the row in the table
to determine proper torque.