TM 10-4510-206-14
Table 4-1.
Quarterly Organizational Preventive Maintenance Checks and Services
Item
No.
1.
2.
3.
ITEM TO BE
INSPECTED
BATH UNIT
Miscellaneous
Assemblies
Shower Stand
Assembly
Water Pump
Assembly
PROCEDURE
1.
Check power cables for loose or broken
connections and cracked or deteriorated insulation.
Check that power supply is properly connected and
identified.
2.
Check to be sure that suction strainer assembly
is positioned away from debris and properly braced.
3.
Check fuel hose assembly for loose
connections, broken, bent or leaky fuel lines and
hoses.
Check fuel supply and return lines to verify
that they are properly connected.
4.
Check drum fill adapter assembly for proper
installation and observe that assembly is not damaged
or that leakage is evident.
1.
Check assembly for missing or damaged risers,
soap dish, or shower curtains.
2.
Check shower nozzles for clogs or damage.
1.
Check pump for proper operation, leaks, and
damage.
2.
Check valves for proper operation and correct
adjustment.
3. Service strainer by removing from housing and
washing thoroughly with clear water.
4-4
Change 4