TM 10-4510-206-14
5-7.
REPAIR PROCEDURES (CONT'D)
n.
Operating Limit and High Limit Controls (Cont'd)
18.
Disconnect nut (20) and turn conduit assembly at connector (21) to
left.
19.
Unscrew operating control (10) by turning counterclockwise.
NOTE
Before installing the replacement operating limit
control, coat threads with pipe joint compound
(14, Appendix E).
5-74