TM 10-4510-206-14
TO 40P1-6-2-1
4-11. SHOW ER STAND ASSEMBLY MAINTENANC E PROCEDURE S (CONT'D)
b. Water Flow Control Valve and Shower Nozzle (Cont'd)
NOTE
Use pipe joint compound (commercial grade)
w h e n j o i n i n g p i p e s a n d f i t t i n g s .
5.
For model PBU-100,
replace defective gasket (7) and assemble shower
h e a d ( 9 ),
a d a p t e r ( 6 ) , g a s k e t ( 7 ) , a n d w a s h e r ( 8 ).
For model HEI-
100,
replace defective gasket (7) and flow washer (8), and assemble
s p r a y c y l i n d e r ( 9 ),
b a l l j o i n t ( 8 a ) a n d b a s e ( 6 ) w i t h g a s k e t ( 7)
and flow washer (8).
6.
For model PBU-100,
i n s t a l l n o z z l e a s s e m b l y ( 5 ) i n v a l v e ( 4 ) by
t u r n i n g c l o c k w i s e .
For model HEI-100,
i n s t a l l n o z z l e a s s e m b l y ( 5)
a n d n i p p l e ( 3 ) i n t o v a l v e ( 4 ) b y t u r n i n g c l o c k w i s e .
C h a n g e 7 4 - 3 1