TM 10-4510-206-14
2-12.
DISMANTLING BATH UNIT FOR MOVEMENT.
These procedures provide instructions for dismantling the Bath Unit and stowing
it for movement.
Perform shutdown procedures in
WARNING
Do not attempt to move the Bath Unit
all electrical power from the unit.
.
paragraph 2-11.
before disconnecting
a.
Disconnect power cable (1) from water heater (2) and from water pump
( 3 ).
b.
Disconnect strainer (4) from water hose.
c.
Disconnect and drain all water hoses (5) from shower stand (6) water
pump (3), mixing valve assembly (7), and water heater (2).
d.
Close fuel valve (paragraph 2-9c).
e.
Disconnect fuel lines connected in paragraphs 2-7p
and 2-7q.
f .
Stow fuel lines to adapter as in paragraph 2-6 k.
g.
Disconnect smoke stack, installed in paragraph 2-7l and 2-7m.
2-30