TM 10-4510-206-14
4-14.
WATER HEATER MAINTENANCE PROCEDURES (CONT'D)
h.
Blower Assembly (Contd)
13.
Place gasket (28) on blower assembly (23). Set blower
(23) in place on water vessel (26) and secure with six
screws (24) and six lockwashers (25).
assembly
hex head
14.
Secure handle assembly (22) to blower housing (23) using two
capscrews (20) and Iockwashers (21).
4-101