Quantcast WATER   PUMP   ASSEMBLY   MAINTENANCE   PROCEDURES Water   pump   assembly   maintenance   is l i m i t e d  t o  r e p a i r  o f  i n l e t  w a t e r  l i n e s t r a i n e r  a n d  e l e c t r i c a l  f i t t i n g s ,  c o n d u i t ,  a n d  w i r i n g . Replace  other  water pump   assembly   components   if   defective. Paint   any   exposed   metal. a. I n l e t   W a t e r   L i n e   S t r a i n e r . Remove   strainer   for   inspection   and c l e a n i n g. Remove   other   defective   components   and   replace. For   item replacement, proceed   as   follows: 1. For   Model   PBU-100   only: a .  Loosen  nut  (1)  and  unscrew  bolt  (2)  and  remove  clamp  (3). b .  R e m o v e  s t r a i n e r  c a p s  ( 4 ) ,  w a s h e r  ( 5 ) ,  a n d  s t r a i n e r  ( 6 )  f r o m s t r a i n e r  h o u s i n g  ( 7 ) . c .   T o   r e p l a c e   s t r a i n e r   h o u s i n g   ( 7 ), r e m o v e   h a l f   c o u p l i n g   ( 8) and   reducer   (9)   and   remove   strainer   housing   (7)   from   nipple (10)   by   turning   counterclockwise. Change   7   4-39